Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  Suncenter refrigerant refrigerant pump export for refrigeration industry
Suncenter refrigerant refrigerant pump export for refrigeration industry

Suncenter refrigerant refrigerant pump export for refrigeration industry

MOQ.
1 Set
Marca
SUNCENTER
Certificado
ISO/CE/SGS
garantia
13 Months
Embalagem
By Plywood case
Porta de envio
Shenzhen/Hongkong
Pagamento
T/T,Western Union,Credit card.
Método de transação
EXW,FOB,DDP,CIF,CFR
Lugar de origem
Guangdong Province, China (Mainland)
Tempo de entrega
Within 10-15 working days after received deposit
Preço
latest_price
latest_price_title
quantity_needed:
pieces
Correio electrónico:

Air driven refrigerant booster pump-SLM06


It's such a device that uses compressed air as power source, air driven refrigerant pump as pressure source and refrigerant as working medium, to get the corresponding high pressure value through regulating air drive pressure; and the ratio of output pressure to air drive pressure is 6:1.


When air drive pressure and outlet pressure reach balance, the refrigerant pump will stop pressurizing, and output pressure will be stable at the preset pressure, so it has such features: explosion-proof, output pressure adjustable, small volume, light weight, easy to operate, reliable performance, wide application range etc.  


Cool operation—No heat generated during liquid transfer. Minor warming during vapor transfer.


No refrigerant heating from the motor.


Safety—Pneumatically driven. Operates from air hose like an air tool. No electrical hazard.


Suncenter refrigerant refrigerant pump export for refrigeration industry-1
  • Air driven refrigerant booster pump-SLM06  


Driving air need

2-8bar

Pressure range

0-48bar

Pressure ratio

6:1

Flow rate

15L/min

Driving air size

ZG1/2

Increasing

63mm

Inlet size

ZG1/2

Stroke

60mm

Outlet size

ZG1/2

Noise

<75dB


DGS- SLM06 model refrigerant pump system


Suncenter refrigerant refrigerant pump export for refrigeration industry-2
  • The standard system including following parts:

  • SLM06 model refrigerant pump

  • Stainless steel frame cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


DGS- SLM06 system = SLM06 booster pump+ following valves, gages, and parts


Suncenter refrigerant refrigerant pump export for refrigeration industry-3


DGS- SLM06 model refrigerant pump system with 16L Accumulator


Suncenter refrigerant refrigerant pump export for refrigeration industry-4
  • DGS- SLM06 model refrigerant pump system with 16L Accumulator


DGS-SLM06 model refrigerant pumps working picture


Suncenter refrigerant refrigerant pump export for refrigeration industry-5
Suncenter refrigerant refrigerant pump export for refrigeration industry-6



features

It's such a device that uses compressed air as power source, air driven refrigerant pump as pressure source and refrigerant as working medium, to get the corresponding high pressure value through  regulating air drive pressure; and the ratio of output pressure to air drive pressure is 6:1. When air drive pressure and outlet pressure reach balance, the refrigerant pump will stop pressurizing, and output pressure will be stable at the preset pressure, so it has such features: explosion-proof, output pressure adjustable, small volume, light weight, easy to operate, reliable performance, wide application range etc.  


  •   Cool operation—No heat generated during liquid transfer. Minor warming during vapor transfer.

  •   No refrigerant heating from the motor. 

  •   Safety—Pneumatically driven. Operates from air hose like an air tool. No electrical hazard. 


video





The fabrics of Suncenter liquid refrigerant pump are processed by the auto digital cutting machine, which will not only keep its shape perfect but also can avoid production mistakes. The use of this product helps in increasing the production of drinks
To ensure the durability of Suncenter liquid refrigerant pump, the production can only be done by our experienced workers with many years of experience in the waterpark field. The product has a reliable electrical system, without any short circuit, or electric leakage occurring
High-end textile manufacturing machines are used in the production ofSuncenter liquid refrigerant pump. It is processed by bale plucker, carding machine, roving frames, or combing machine. It has a robust design, supported by an aluminum plate
Suncenter refrigerant pump is manufactured adopting CNC machines. Programs for the CNC machines are created in advance by our dedicated CAD/CAM specialists working with the latest equipment. The product is easy to clean with no blind corners
Suncenter liquid refrigerant pump is designed with delicate water treating system, ranging from pretreatment, refine filtration, and sterilization process, and all these processes achieve better purification effect. Equipped with a safety system, the product can detect the faults
The product is 100% qualified in terms of the functionality, specification/size, durability. The product generates little noise during operation
Mensagem do produto
Bate-papo Online 编辑模式下无法使用
Deixe sua mensagem inputting