Tornar-se o especialista em controle de fluido de alta pressão no mundo

Suncenter  >  AI - Page Sitemap  >  Suncenter high reputation gas booster for safety valve calibration
Suncenter high reputation gas booster for safety valve calibration

Suncenter high reputation gas booster for safety valve calibration

MOQ.
1 Set
Marca
SUNCENTER
Certificado
ISO/CE/SGS
garantia
13 Months
Embalagem
By Plywood case
Porta de envio
Shenzhen/Hongkong
Pagamento
T/T,Western Union,Credit card.
Método de transação
EXW,FOB,DDP,CIF,CFR
Lugar de origem
Guangdong Province, China (Mainland)
Tempo de entrega
Within 10-15 working days after received deposit
Preço
latest_price
latest_price_title
quantity_needed:
pieces
Correio electrónico:
Company Advantages
1. Suncenter oxygen booster pump is of flexible design. It can be designed for front or back projection, the more common being front projection systems, which have the image source situated on the same side of the screen as the audience. It can be used for a broad variety of liquids, such as oil, water, and chemical
2. As the demand for global bases increases, the market prospects for this product are optimistic. The product is consistently recognized as a reliable one in the industry
3. The product has the advantage of strong compatibility. It can perfectly work with other mechanical systems to bring out the best results. The speed of this product is infinitely variable
4. The product is not likely to accumulate too much heat. Its powerful cooling system is designed to maintain the proper temperature of mechanical parts, allowing it to have good heat dissipation. This product has the characteristics of explosion proof
5. The product has the advantage of stable mechanical properties. Having been treated under extremely cold temperatures, its mechanical components are tensile enough to withstand extreme industrial conditions. It helps save costs and prevent contamination

Compressed Air Driven Gas Booster Pump- DGT Series


Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:


Applications for Air Driven Gas Boosters


SUNCENTER Air Driven Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.


Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.


As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities.


SUNCENTER Air Driven Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; Automobile regulator detecting and telecommunication cable inflatable appliances.


Suncenter high reputation gas booster for safety valve calibration-1



DGT series gas booster pumps(Double acting, double stage, single air drive head ):


Suncenter high reputation gas booster for safety valve calibration-2
  • DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure.  

  • DGT pumps are available with high quality seals, which provide significantly better service life  

  • All parts in contact with the gas are made of stainless steel. 


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )


2DGT series gas booster pumps(Double acting, double stage,double air driven heads ):


Suncenter high reputation gas booster for safety valve calibration-3
  • 2DGT series gas booster pumps(Double acting, double stage,double air driven heads ) 


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

2DGT7/15

15:1

4

56

120

2bar-8 bar

15XPL

3/8 / 3/8

430(at PA of 10 bar )

2DGT7/25

25:1

5

56

200

2bar-8 bar

25XPL

3/8 / 3/8

300(at PA of 10 bar )

2DGT15/40

40:1

7

120

320

2bar-8 bar

40XPL

3/8 / 3/8

180(at PA of 10 bar )

2DGT15/60

60:1

7

120

480

2bar-8 bar

60XPL

3/8 / 3/8

120(at PA of 10 bar )



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar  

  •   No airline lubricator required

  •   Hydrocarbon free - separation between air and gas sections

  •   Pressures to 80Mpa (11,600 psi)

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof  

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant 

  •   Applicable gas:Air/Ar(Argon)/He(Helium)/H2(Hydrogen)/O2(Oxygen)N2(Nitrogen) CO2/NO2/CH4/C2H2/LNG/LPG/CNG/FM200/SF6/H2S etc


video





Company Features
1. Owing to the service of our professional team, Suncenter now has received high recommendation from clients.
2. Different mechanisms are provided for fabricating different gas booster .
3. We have a great dream that Dongguan Suncenter Fluid Control Equipment Co., Ltd one day will become a professional pump booster enterprise. Get more info!
Our pump booster are all selected high-quality materials and made by fine processing, with excellent workmanship, excellent performance, beautiful appearance and high quality.
Based on the selection of high-quality materials and the application of exquisite craftsmanship, gas booster has a reasonable structure and excellent performance, durable, and is a trustworthy high-quality product.
Actively study and introduce world-class management theories, establish a comprehensive quality management system, and implement the concept of product quality control throughout the entire process of product design, production, inspection, and use, and carry out quality control with full participation, It is better to ensure that the oxygen booster pump produced is always of consistent quality and excellent quality.
As a professional pump booster manufacturer, has rich production experience, advanced production equipment, superb production technology and strong production strength, capable of producing high-quality pump booster.
Constantly upgrade and renew production equipment and production lines, and explore technologies and processes to ensure that the overall quality of gas booster produced is more reliable.
Many customers are satisfied with the high quality of this product.
Mensagem do produto
Bate-papo Online 编辑模式下无法使用
Deixe sua mensagem inputting