Tornar-se o especialista em controle de fluido de alta pressão no mundo

Suncenter  >  AI - Page Sitemap  >  Suncenter fire fire extinguisher refill station marketing for fire extinguisher
Suncenter fire fire extinguisher refill station marketing for fire extinguisher

Suncenter fire fire extinguisher refill station marketing for fire extinguisher

MOQ.
1 Set
Marca
SUNCENTER
Certificado
ISO/CE/SGS
garantia
13 Months
Embalagem
By Plywood case
Porta de envio
Shenzhen/Hongkong
Pagamento
T/T,Western Union,Credit card.
Método de transação
EXW,FOB,DDP,CIF,CFR
Lugar de origem
Guangdong Province, China (Mainland)
Tempo de entrega
Within 10-15 working days after received deposit
Preço
latest_price
latest_price_title
quantity_needed:
pieces
Correio electrónico:
Company Advantages
1. To ensure the quality of Suncenter fire extinguisher refill station , the first-rate materials are used in the production, which acts as an important role in guaranteeing the basic quality assurance. It requires no electrical or mechanical drive connections
2. Dongguan Suncenter Fluid Control Equipment Co., Ltd's dedicated team strives to be the best in the industry. The speed of this product can be adjusted steplessly
3. The product is able to maintain a clean appearance. It has a special coated surface which can effectively prevent adhesion of dust and oil smoke during operation. It is automated with many modification and control options available
4. The product has the required fatigue resistance. It has the ability to withstand cyclic fatigue loading to support itself until the tasks are finished. The product is consistently recognized as a reliable one in the industry

FM-200(HFC-227ea)/ NOVEC automatic filling machine



Machine Composition

DGS-FM-5A model filling machine including air-driven gas filling pump, precision pressure gauge, pressure reducing valve, high pressure electromagnetic valve, electric control part, and electronic scale, vacuum pump, etc.



Machine characteristics

DGS-FM-5A model filling machine using the compressed air as power source, Through the Suncenter air driven gas booster and filling pump, driving the FM200/NOVEC filling and conveying, when the transmission weight reaches a certain value, the sensor signal is transferred to the gas electromagnetic valve, the driven air will stop automaticlly,and pump stops working.

Then Connecting the  nitrogen gas source, open the high-pressure nitrogen gas valve and start the injection of nitrogen; when precision pressure gauge shows the needed nitrogen pressure then close the nitrogen valve; filling finished; It has the characteristics of small volume, light weight, simple operation, reliable performance. Especially suitable for the filling of FM-200/NOVEC in fire fighting industry.


Suncenter fire fire extinguisher refill station marketing for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Suncenter fire fire extinguisher refill station marketing for fire extinguisher-2


video





Company Features
1. fire extinguisher refill station is the result of high technology.
2. We aim to sustain a responsible supply chain that has a minimal environmental impact and corporate with a manufacturing supplier base that supports and adheres to our expected corporate and social standards.
The raw materials of Suncenter fire extinguisher refill station are extracted with the help of various technology. The advanced digging technology and the environmental control systems for managing airflow, water flow, and temperature guide the whole preliminary process. There is no heat generated during liquid transfer
The electrolytes of Suncenter fire extinguisher refill station are well treated to have high ionic conductivity and good wetting characteristics, particularly for high power applications. This product brings no vibration and noise
Suncenter fire extinguisher filling equipment is checked by conducting on-site testing including marking and vulcanization tests for rubber outsoles, rocking tests, fabric testing and verification of special features like waterproofing and stain resistance. It has flexibility without the use of unloaders or bypass valves
Different high technologies are used in the production of Suncenter fire extinguisher refill station. In order to enhance its adjusting ability and compatibility with the power grid, it makes full use of the comprehensive technical support technology for solar power generation. Its output pressure can be easily adjustable
Suncenter fire extinguisher filling equipment has undergone a series of the assessment process in terms of its sizes (width, height, length), colors, and resistance to environmental conditions (rain, wind, snow, sand storms, etc.) This product can be installed at any predetermined pressure
The product is durable. The encapsulation material of the battery is manufactured with high quality to enhance cell performance and provide a longer service life. The product is easy to maintain and helps improve productivity
Mensagem do produto
Bate-papo Online 编辑模式下无法使用
Deixe sua mensagem inputting