MOQ.
1 Set
Marca
SUNCENTER
Certificado
ISO/CE/SGS
garantia
13 Months
Embalagem
By Plywood case
Porta de envio
Shenzhen/Hongkong
Pagamento
T/T,Western Union,Credit card.
Método de transação
EXW,FOB,DDP,CIF,CFR
Lugar de origem
Guangdong Province, China (Mainland)
Tempo de entrega
Within 10-15 working days after received deposit
Preço
latest_price
latest_price_title
quantity_needed:
pieces
Correio electrónico:

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


Suncenter cylinder fire extinguisher refill station bulk production for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


Suncenter cylinder fire extinguisher refill station bulk production for fire extinguisher-2
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


Suncenter cylinder fire extinguisher refill station bulk production for fire extinguisher-3
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


Suncenter cylinder fire extinguisher refill station bulk production for fire extinguisher-4
Suncenter cylinder fire extinguisher refill station bulk production for fire extinguisher-5


video





The raw materials of Suncenter fire extinguisher refill station are extracted with the help of various technology. The advanced digging technology and the environmental control systems for managing airflow, water flow, and temperature guide the whole preliminary process. The product is suitable for most liquids and liquefied gases
The electrolytes of Suncenter fire extinguisher filling equipment are well treated to have high ionic conductivity and good wetting characteristics, particularly for high power applications. This product brings no vibration and noise
Suncenter fire extinguisher filling equipment is checked by conducting on-site testing including marking and vulcanization tests for rubber outsoles, rocking tests, fabric testing and verification of special features like waterproofing and stain resistance. Its output pressure can be easily adjustable
Different high technologies are used in the production of Suncenter fire extinguisher filling equipment. In order to enhance its adjusting ability and compatibility with the power grid, it makes full use of the comprehensive technical support technology for solar power generation. The product is consistently recognized as a reliable one in the industry
Suncenter fire extinguisher filling equipment has undergone a series of the assessment process in terms of its sizes (width, height, length), colors, and resistance to environmental conditions (rain, wind, snow, sand storms, etc.) Its output pressure can be easily adjustable
The product is durable. The encapsulation material of the battery is manufactured with high quality to enhance cell performance and provide a longer service life. This product features energy saving and environmental protection
Mensagem do produto
Bate-papo Online 编辑模式下无法使用
Deixe sua mensagem inputting