Tornar-se o especialista em controle de fluido de alta pressão no mundo

Suncenter  >  AI - Page Sitemap  >  environmental fire extinguisher refill station filling type for fire extinguisher
environmental fire extinguisher refill station filling type for fire extinguisher

environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher

environmental fire extinguisher refill station filling type for fire extinguisher

By adopting advanced technology, the quality of this product can be assured.
latest_price_title
quantity_needed:
pieces
Correio electrónico:
Application Scope
The hydro test pump developed by Suncenter Fluid Control Equipment is widely used in various fields.With a focus on customers' potential needs, Suncenter Fluid Control Equipment has the ability to provide one-stop solutions.
Product Comparison
Suncenter Fluid Control Equipment's booster pumps has been substantially improved in a scientific way, as shown in the following aspects.
Company Advantages
1. fire extinguisher refill station from Dongguan Suncenter Fluid Control Equipment Co., Ltd adopts a new type of fire extinguisher refilling machine material.
2. By adopting advanced technology, the quality of this product can be assured.
3. This product perfectly matches people's personality and their outfits, which is why so many people have tried their hand at it.

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


environmental fire extinguisher refill station filling type for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


environmental fire extinguisher refill station filling type for fire extinguisher-2
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


environmental fire extinguisher refill station filling type for fire extinguisher-3
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


environmental fire extinguisher refill station filling type for fire extinguisher-4
environmental fire extinguisher refill station filling type for fire extinguisher-5


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd is dedicated to the manufacturing and R&D of fire extinguisher refill station .
2. The quality of fire extinguisher refill can be guaranteed by our experienced technicians.
3. We use automatic filling machine to connect the future. Please contact us! High quality customer service of Suncenter is highly commented by customers. Please contact us!
Suncenter fire extinguisher refill station has been evaluated by process. It has been tested in terms of color, color fastness (friction test), and safety of accessories. This product has been certified under CE and RoHS
Suncenter fire extinguisher refill goes through elaborate design steps. They are problem definition, basic need definition, material analysis, detailed design, and preparation of drawing. This product can be used in many different industries such as food & beverage, water, energy, pharmaceutical, etc
Suncenter fire extinguisher refilling machine is always carefully packaged before shippment. Additional information about the warranty, safety and care of the product is also included in the packaging. It generates only little magnetic interference
Suncenter fire extinguisher refill is a product developed by our R&D team. They strive to produce light products with good thermal convection properties to increase product durability. This product has a high level of IP
Once the Suncenter fire extinguisher refilling machine production is completed, the quality assessment will be carried out. We will strictly check fiber strength, water shrinkage, colorfastness, weaving strength and other parameters. This product is not susceptible to cracks
The product has no potential risks of electrical shock. It has passed ground continuity testing which can prevent unsuitable current from creating and flows to the earth. This product has a wide range of operating temperatures
Mensagem do produto
Bate-papo Online 编辑模式下无法使用
Deixe sua mensagem inputting